YOUR ACCOUNT
BASKET
CHECKOUT
AUTOMATION & CONTROL DISTRIBUTORS
T: 01482 225297 email: sales@seltec.co.uk
Unit G, Venture Business Park
Witty Street
Hull
HU3 4EL
United Kingdom
Search Products
Subscribe to Newsletter
Enter your email address in the box above to receive monthly newsletters from us.
FLASHTRAB lightning protection from Phoenix ContactPhoenix Contact
PRODUCTS

FLASHTRAB Lightning current and surge arresters

Download the TRABTECH. Ahead of its time FLASHTRAB compact. Simply ingenious - Ingeniously simple flyer (498K)

  FLASHTRAB Lightning current and surge arresters    
Phoenix Contact 2859712 FLT-CP-3S-350
Phoenix Contact - Germany
2859712 FLT-CP-3S-350
Arrestor combination for 5 conductor networks
L1, L2, L3, N, PE
Pluggable modules
Base can be turned 180 degrees. Feed lines can come in from the top or bottom.
Relay output for remote signaling of trip.
Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 3-phase power supply networks with separately installed PE and N (L1, L2, L3, PE, N).

  2859712 FLT-CP-3S-350  
Pheonix Contact 2859725 FLT-CP-3C-350
Phoenix Contact - Germany
2859725 FLT-CP-3C-350
Arrestor combination for 4 conductor networks
L1, L2, L3, PEN
Pluggable modules
Base can be turned 180 degrees. Feed lines can come in from the top or bottom.
Relay output for remote signaling of trip.
Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 3-phase power supply networks with PE and N (L1, L2, L3, PEN) installed in one cable.

  2859725 FLT-CP-3C-350  
Phoenix Contact 2859767 FLT-CP-2S-350
Phoenix Contact - Germany
2859767 FLT-CP-2S-350
Arrestor combination for 4 conductor networks
L1, L2, N, PE
Pluggable modules
Base can be turned 180 degrees. Feed lines can come in from the top or bottom.
Relay output for remote signaling of trip.
Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 2-phase power supply networks with separately installed PE and N (L1, L2, PE, N).

  2859767 FLT-CP-2S-350  
Phoenix Contact 2859770 FLT-CP-2C-350
Phoenix Contact - Germany
2859770 FLT-CP-2C-350
Arrestor combination for 3 conductor networks
L1, L2, PEN
Pluggable modules
Base can be turned 180 degrees. Feed lines can come in from the top or bottom.
Relay output for remote signaling of trip.
Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 2-phase power supply networks with PE and N (L1, L2, PEN) installed in one cable.

  2859770 FLT-CP-2C-350  
Phoenix Contact 2859738 FLT-CP-1S-350
Phoenix Contact - Germany
2859738 FLT-CP-1S-350
Arrestor combination for single phase power supply system
L1, N, PE
Pluggable modules
Base can be turned 180 degrees. Feed lines can come in from the top or bottom.
Relay output for remote signaling of trip.
Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 1-phase power supply networks with separately installed PE and N (L1, PE, N).

  2859738 FLT-CP-1S-350  
Phoenix Contact 2859741 FLT-CP-1C-350
Phoenix Contact - Germany
2859741 FLT-CP-1C-350
Arrestor combination for L1, PEN
Pluggable modules
Base can be turned 180 degrees. Feed lines can come in from the top or bottom.
Relay output for remote signaling of trip.
Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 1-phase power supply networks with PE and N (L1, PEN) installed in one cable.

  2859741 FLT-CP-1C-350  
Phoenix Contact 2859754 FLT-CP-N/PE-350
Phoenix Contact - Germany
2859754 FLT-CP-N/PE-350
Arrestor N/PE
Pluggable modules
Base can be turned 180 degrees. Feed lines can come in from the top or bottom.
Relay output for remote signaling of trip.
Encapsulated pluggable Class I arresters as N/PE spark gap with an ignition mechanism for triggering the sparkover voltage.

  2859754 FLT-CP-N/PE-350