| FLASHTRAB Lightning current and surge arresters |
|
|
|
|
|
| Phoenix Contact - Germany |
2859712 FLT-CP-3S-350 Arrestor combination for 5 conductor networks L1, L2, L3, N, PE |
| Pluggable modules |
| Base can be turned 180 degrees. Feed lines can come in from the top or bottom. |
| Relay output for remote signaling of trip. |
| Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 3-phase power supply networks with separately installed PE and N (L1, L2, L3, PE, N). |
|
|
2859712 FLT-CP-3S-350
|
|
 |
|
|
|
| Phoenix Contact - Germany |
2859725 FLT-CP-3C-350 Arrestor combination for 4 conductor networks L1, L2, L3, PEN |
| Pluggable modules |
| Base can be turned 180 degrees. Feed lines can come in from the top or bottom. |
| Relay output for remote signaling of trip. |
| Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 3-phase power supply networks with PE and N (L1, L2, L3, PEN) installed in one cable. |
|
|
2859725 FLT-CP-3C-350
|
|
 |
|
|
|
| Phoenix Contact - Germany |
2859767 FLT-CP-2S-350 Arrestor combination for 4 conductor networks L1, L2, N, PE |
| Pluggable modules |
| Base can be turned 180 degrees. Feed lines can come in from the top or bottom. |
| Relay output for remote signaling of trip. |
| Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 2-phase power supply networks with separately installed PE and N (L1, L2, PE, N). |
|
|
2859767 FLT-CP-2S-350
|
|
 |
|
|
|
| Phoenix Contact - Germany |
2859770 FLT-CP-2C-350 Arrestor combination for 3 conductor networks L1, L2, PEN |
| Pluggable modules |
| Base can be turned 180 degrees. Feed lines can come in from the top or bottom. |
| Relay output for remote signaling of trip. |
| Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 2-phase power supply networks with PE and N (L1, L2, PEN) installed in one cable. |
|
|
2859770 FLT-CP-2C-350
|
|
 |
|
|
|
| Phoenix Contact - Germany |
2859738 FLT-CP-1S-350 Arrestor combination for single phase power supply system L1, N, PE |
| Pluggable modules |
| Base can be turned 180 degrees. Feed lines can come in from the top or bottom. |
| Relay output for remote signaling of trip. |
| Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 1-phase power supply networks with separately installed PE and N (L1, PE, N). |
|
|
2859738 FLT-CP-1S-350
|
|
 |
|
|
|
| Phoenix Contact - Germany |
2859741 FLT-CP-1C-350 Arrestor combination for L1, PEN |
| Pluggable modules |
| Base can be turned 180 degrees. Feed lines can come in from the top or bottom. |
| Relay output for remote signaling of trip. |
| Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 1-phase power supply networks with PE and N (L1, PEN) installed in one cable. |
|
|
2859741 FLT-CP-1C-350
|
|
 |
|
|
|
| Phoenix Contact - Germany |
2859754 FLT-CP-N/PE-350 Arrestor N/PE |
| Pluggable modules |
| Base can be turned 180 degrees. Feed lines can come in from the top or bottom. |
| Relay output for remote signaling of trip. |
| Encapsulated pluggable Class I arresters as N/PE spark gap with an ignition mechanism for triggering the sparkover voltage. |
|
|
2859754 FLT-CP-N/PE-350
|
|
 |
|
|
|
|
|
Special offers |
|
Sensors |
|
Motor Control Solutions |
|
Safety Products |
|
Shaft Encoders |
|
Switchgear & Panel Indicators |
|
Instrumentation |
|
DIN Rail Terminals |
|
Power Supplies |
|
RFID |
|
Electronic Housings |
|
PCB terminals - COMBICON |
|
Serial interface connectors |
|
Interface relays |
|
Surge Protection |
|
Industrial Ethernet |
|
Energy Monitoring |
|
Cable management |
|
Tools |
|
Photovoltaic Products |
|
|