| IFM Electronic - Germany | IIT001 IIK2014BARKA/M/V4A/LS-104AK Inductive sensor for hygenic and wet areas AC/DC, N/O, 14mm, Flush, 1/2" plug | | Output signal | AC/DC 2-wire Normally open | | Housing material | V4A, PEEK face | | Connection | 1/2" connector | | Diameter | M30x1.5 | | Length (mm) | 70.0 | | Installation | Flush | | Sensing range Sn (mm) | 14.0 | | Frequency | 25Hz (AC), 100 Hz (DC) | | Protection | IP68/IP69K | | Operating voltage | 20-140Vac/dc | | Temperature | 0 to +100C |
|
|
IFM IIK2014BARKA/M/V4A/LS-104AK (IIT001)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT002 IIK2022-ARKA/M/V4A/LS-104AK Inductive sensor for hygenic and wet areas AC/DC, N/O, 22mm, Non-flush, 1/2" plug | | Output signal | AC/DC 2-wire Normally open | | Housing material | V4A, PEEK face | | Connection | 1/2" connector | | Diameter | M30x1.5 | | Length (mm) | 70.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 22.0 | | Frequency | 25Hz (AC), 100 Hz (DC) | | Protection | IP68/IP69K | | Operating voltage | 20-140Vac/dc | | Temperature | 0 to +100C |
|
|
IFM IIK2022-ARKA/M/V4A/LS-104AK (IIT002)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT200 IIB3022-BPKG/M/V4A/US-102-DPS Inductive sensor for hygenic and wet areas PNP, N/O, 22mm, Non-flush, M12 plug | | Output signal | PNP Normally open | | Housing material | V4A, PEEK face | | Connection | M12 plug | | Diameter | M30x1.5 | | Length (mm) | 51.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 22.0 | | Frequency | 100Hz | | Protection | IP68/IP69K | | Operating voltage | 10-36Vdc | | Temperature | 0 to +100C |
|
|
IFM IIB3022-BPKG/M/V4A/US-102-DPS (IIT200)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT202 IIKC022-ASKG/M/V4A/US-100-DRS Inductive sensor for hygenic and wet areas PNP/NPN, N/O, 22mm, Non-flush, M12 plug, 3 or 2 wire | | Output signal | 3-wire DC PNP; 2-wire DC PNP/NPN; Normally open | | Housing material | V4A, PEEK face | | Connection | M12 plug | | Diameter | M30x1.5 | | Length (mm) | 70.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 22.0 | | Frequency | 100Hz | | Protection | IP68/IP69K | | Operating voltage | 10-36Vdc | | Temperature | 0 to +100C |
|
|
IFM IIKC022-ASKG/M/V4A/US-100-DRS (IIT202)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT204 IIKC012BASKG/M/V4A/US-100-DRS Inductive sensor for hygenic and wet areas PNP/NPN, N/O, 14mm, Flush, M12 plug, 3 or 2 wire | | Output signal | 3-wire DC PNP; 2-wire DC PNP/NPN; Normally open | | Housing material | V4A, PEEK face | | Connection | M12 plug | | Diameter | M30x1.5 | | Length (mm) | 70.0 | | Installation | Flush | | Sensing range Sn (mm) | 14.0 | | Frequency | 50Hz | | Protection | IP68/IP69K | | Operating voltage | 10-36Vdc | | Temperature | 0 to +100C |
|
|
IFM IIKC012BASKG/M/V4A/US-100-DRS (IIT204)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT205 IIB3012BBPKG/M/V4A/US-102-DPS Inductive sensor for hygenic and wet areas PNP, N/O, 14mm, Flush, M12 plug | | Output signal | PNP Normally open | | Housing material | V4A, PEEK face | | Connection | M12 plug | | Diameter | M30x1.5 | | Length (mm) | 50.0 | | Installation | Flush | | Sensing range Sn (mm) | 14.0 | | Frequency | 50Hz | | Protection | IP68/IP69K | | Operating voltage | 10-36Vdc | | Temperature | 0 to +100C |
|
|
IFM IIB3012BBPKG/M/V4A/US-102-DPS (IIT205)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT206 IIB3014BBPKG/M/V4A/10m/WH Inductive sensor for hygenic and wet areas PNP, N/O, 14mm, Flush, cable 10m | | Output signal | PNP Normally open | | Housing material | V4A, PEEK face | | Connection | Cable, 10m PVC | | Diameter | M30x1.5 | | Length (mm) | 59.0 | | Installation | Flush | | Sensing range Sn (mm) | 14.0 | | Frequency | 100Hz | | Protection | IP68/IP69K | | Operating voltage | 10-36Vdc | | Temperature | 0 to +100C |
|
|
IFM IIB3014BBPKG/M/V4A/10m/WH (IIT206)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT207 IIB3022-BPKG/M/V4A/6M/WH Inductive sensor for hygenic and wet areas PNP, N/O, 22mm, Non-flush, cable 6m | | Output signal | PNP Normally open | | Housing material | V4A, PEEK face | | Connection | Cable, 6m PVC | | Diameter | M30x1.5 | | Length (mm) | 59.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 22.0 | | Frequency | 100Hz | | Protection | IP68/IP69K | | Operating voltage | 10-36Vdc | | Temperature | 0 to +100C |
|
|
IFM IIB3022-BPKG/M/V4A/6M/WH (IIT207)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT208 IIB3022-BPKG/M/V4A/10m/WH Inductive sensor for hygenic and wet areas PNP, N/O, 22mm, Non-flush, cable 10m | | Output signal | PNP Normally open | | Housing material | V4A, PEEK face | | Connection | Cable, 10m PVC | | Diameter | M30x1.5 | | Length (mm) | 59.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 22.0 | | Frequency | 100Hz | | Protection | IP68/IP69K | | Operating voltage | 10-36Vdc | | Temperature | 0 to +100C |
|
|
IFM IIB3022-BPKG/M/V4A/10m/WH (IIT208)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT209 IIB3014BBPKG/M/V4A/6M/WH Inductive sensor for hygenic and wet areas PNP, N/O, 14mm, Flush, cable 6m | | Output signal | PNP Normally open | | Housing material | V4A, PEEK face | | Connection | Cable, 6m PVC | | Diameter | M30x1.5 | | Length (mm) | 59.0 | | Installation | Flush | | Sensing range Sn (mm) | 14.0 | | Frequency | 100Hz | | Protection | IP68/IP69K | | Operating voltage | 10-36Vdc | | Temperature | 0 to +100C |
|
|
IFM IIB3014BBPKG/M/V4A/6M/WH (IIT209)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT210 IIKC014BASKG/M/V4A/10M Inductive sensor for hygenic and wet areas PNP/NPN, N/O, 14mm, Flush, 10m cable, 3 or 2 wire | | Output signal | 3-wire DC PNP; 2-wire DC PNP/NPN; Normally open | | Housing material | V4A, PEEK face | | Connection | Cable, 10m PVC | | Diameter | M30x1.5 | | Length (mm) | 81.0 | | Installation | Flush | | Sensing range Sn (mm) | 14.0 | | Frequency | 100Hz | | Protection | IP68/IP69K | | Operating voltage | 10-36Vdc | | Temperature | 0 to +100C |
|
|
IFM IIKC014BASKG/M/V4A/10M (IIT210)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT212 IIK3015BBPKG/M/V4A/US104-DPS Inductive sensor for hygenic and wet areas PNP, N/O, 15mm, Flush, M12 plug | | Output signal | PNP Normally open | | Housing material | V4A, PEEK face | | Connection | M12 plug | | Diameter | M30x1.5 | | Length (mm) | 70.0 | | Installation | Flush | | Sensing range Sn (mm) | 15.0 | | Frequency | 100Hz | | Protection | IP68/IP69K | | Operating voltage | 10-36Vdc | | Temperature | 0 to +100C |
|
|
IFM IIK3015BBPKG/M/V4A/US104-DPS (IIT212)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT213 IIK3022-BPKG/M/V4A/US104-DPS Inductive sensor for hygenic and wet areas PNP, N/O, 22mm, Non-flush, M12 plug | | Output signal | PNP Normally open | | Housing material | V4A, PEEK face | | Connection | M12 plug | | Diameter | M30x1.5 | | Length (mm) | 70.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 22.0 | | Frequency | 100Hz | | Protection | IP68/IP69K | | Operating voltage | 10-36Vdc | | Temperature | 0 to +100C |
|
|
IFM IIK3022-BPKG/M/V4A/US104-DPS (IIT213)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT218 IIK3015BAPKG/M/V4A/US Inductive sensor for hygenic and wet areas PNP, N/O, 15mm, Flush, M12 plug | | Output signal | PNP Normally closed | | Housing material | V4A, PEEK face | | Connection | M12 plug | | Diameter | M30x1.5 | | Length (mm) | 70.0 | | Installation | Flush | | Sensing range Sn (mm) | 15.0 | | Frequency | 100Hz | | Protection | IP68/IP69K | | Operating voltage | 10-36Vdc | | Temperature | 0 to +100C |
|
|
IFM IIK3015BAPKG/M/V4A/US (IIT218)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT219 IIK3022-APKG/M/V4A/US104-DPO Inductive sensor for hygenic and wet areas PNP, N/C, 22mm, Non-flush, M12 plug | | Output signal | PNP Normally closed | | Housing material | V4A, PEEK face | | Connection | M12 plug | | Diameter | M30x1.5 | | Length (mm) | 70.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 22.0 | | Frequency | 100Hz | | Protection | IP68/IP69K | | Operating voltage | 10-36Vdc | | Temperature | 0 to +100C |
|
|
IFM IIK3022-APKG/M/V4A/US104-DPO (IIT219)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT228 IIK3010-BPKG/AM/US-104-DPS Inductive sensor for hygenic and wet areas PNP, N/O, 10mm, Flush, M12 plug | | Output signal | PNP Normally open | | Housing material | V4A stainless steel | | Connection | M12 plug | | Diameter | M30x1.5 | | Length (mm) | 70.0 | | Installation | Flush | | Sensing range Sn (mm) | 10.0 | | Frequency | 50Hz | | Protection | IP68/IP69K | | Operating voltage | 10-36Vdc | | Temperature | 0 to +100C |
|
|
IFM IIK3010-BPKG/AM/US-104-DPS (IIT228)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT20A IIB3012BBPKG/M/V4A/US102DPS/3D Inductive sensors, ATEX approval Group II, category 3D PNP, N/O, 14mm, Flush, M12 plug, ATEX | | Output signal | PNP Normally open | | Housing material | V4A, PEEK face | | Connection | M12 plug | | Diameter | M30x1.5 | | Length (mm) | 50.0 | | Installation | Flush | | Sensing range Sn (mm) | 14.0 | | Frequency | 100Hz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | 0 to +60C |
|
|
IFM IIB3012BBPKG/M/V4A/US102DPS/3D (IIT20A)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT21A IIB3022-BPKG/M/V4A/US/3D Inductive sensors, ATEX approval Group II, category 3D PNP, N/O, 22mm, Non-flush, M12 plug, ATEX | | Output signal | PNP Normally open | | Housing material | V4A, PEEK face | | Connection | M12 plug | | Diameter | M30x1.5 | | Length (mm) | 50.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 22.0 | | Frequency | 100Hz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | 0 to +60C |
|
|
IFM IIB3022-BPKG/M/V4A/US/3D (IIT21A)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT22A IIB3014BBPKG/M/V4A/US104DPS/3G Inductive sensors, ATEX approval Group II, category 3D/3G PNP, N/O, 14mm, Flush, M12 plug, ATEX | | Output signal | PNP Normally open | | Housing material | V4A, PEEK face | | Connection | M12 plug | | Diameter | M30x1.5 | | Length (mm) | 50.0 | | Installation | Flush | | Sensing range Sn (mm) | 14.0 | | Frequency | 100Hz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | 0 to +60C |
|
|
IFM IIB3014BBPKG/M/V4A/US104DPS/3G (IIT22A)
|
|
 |
|
|
|
| IFM Electronic - Germany | IIT23A IIKC014BASKG/V4A/US/2LED/2D Inductive sensors, ATEX approval Group II, category 2D PNP, N/O, 14mm, Flush, M12 plug, ATEX | | Output signal | PNP Normally open | | Housing material | V4A, PEEK face | | Connection | M12 plug | | Diameter | M30x1.5 | | Length (mm) | 70.0 | | Installation | Flush | | Sensing range Sn (mm) | 14.0 | | Frequency | 100Hz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | 0 to +60C |
|
|