| M30 |
|
|
|
|
|
| Rechner Sensors - Germany | | KA0747 KAS-95-A24-1CO-K-POM | Change-over, AC/DC | | Connection | PVC cable, 2m | | Output signal | Change-over relay. 1A/250Vac | | Operating voltage | 20-250VAC/VDC | | Diameter | M30 x 1.5 | | Installation | Non-flush mountable | | Housing material | POM (Lid PA) | | Operating distance Sn (mm) | 15mm | | Operating distance Smax (mm) | 2-20mm | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 2Hz | | Certification | CE, RoHS | |
|
KA0747 KAS-95-A24-1CO-K-POM
|
|
 |
|
|
|
| Rechner Sensors - Germany | | KA0747 KAS-95-A24-1CO-K | Change-over, AC/DC | | Connection | PVC cable, 2m | | Output signal | Change-over relay. 1A/250Vac | | Operating voltage | 20-250VAC/VDC | | Diameter | M30 x 1.5 | | Installation | Non-flush mountable | | Housing material | PBT (Lid PA/PPO) | | Operating distance Sn (mm) | 15mm | | Operating distance Smax (mm) | 2-20mm | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 2Hz | | Certification | CE, RoHS | |
|
KA0800 KAS-95-A24-1CO-K
|
|
 |
|
|
|
| Rechner Sensors - Germany | KA0748 KAS-95-A24-1CO-K-POM-TD | Change-over, AC/DC With time delays | | Connection | PVC cable, 2m | | Output signal | Change-over relay. 1A/250Vac | | Operating voltage | 20-250VAC/VDC | | Timers | Selectable ON or OFF delays. 1sec to 10min | | Diameter | M30 x 1.5 | | Installation | Non-flush mountable | | Housing material | POM (Lid PA) | | Operating distance Sn (mm) | 15mm | | Operating distance Smax (mm) | 2-20mm | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 2Hz | | Certification | CE, RoHS | |
|
KA0748 KAS-95-A24-1CO-K-POM-TD
|
|
 |
|
|
|
| Rechner Sensors - Germany | KA0749 KAS-95-A24-1CO-K-POM-OND | Change-over, AC/DC With time delays | | Connection | PVC cable, 2m | | Output signal | Change-over relay. 1A/250Vac | | Operating voltage | 20-250VAC/VDC | | Timers | Selectable ON delay. 1sec to 10min | | Diameter | M30 x 1.5 | | Installation | Non-flush mountable | | Housing material | POM (Lid PA) | | Operating distance Sn (mm) | 15mm | | Operating distance Smax (mm) | 2-20mm | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 2Hz | | Certification | CE, RoHS | |
|
KA0749 KAS-95-A24-1CO-K-POM-OND
|
|
 |
|
|
|
| Rechner Sensors - Germany | KA0750 KAS-95-A24-1CO-K-POM-OFD | Change-over, AC/DC With time delays | | Connection | PVC cable, 2m | | Output signal | Change-over relay. 1A/250Vac | | Operating voltage | 20-250VAC/VDC | | Timers | Selectable OFF delay. 1sec to 10min | | Diameter | M30 x 1.5 | | Installation | Non-flush mountable | | Housing material | POM (Lid PA) | | Operating distance Sn (mm) | 15mm | | Operating distance Smax (mm) | 2-20mm | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 2Hz | | Certification | CE, RoHS | |
|
KA0750 KAS-95-A24-1CO-K-POM-OFD
|
|
 |