| PRODUCTS |
|
NormLine sensors
Rechner Sensors LOW COST standard capacitive sensors.
Capacitive sensors just like inductive and optical sensors are subject to a harmonised norm IEC 60947-5-2. All the main important technical data and features are stated within this norm. Meeting these standards makes life easy for the user with regard to selection and replacement of sensors.
NormLine sensors guarantee a free trade in the common market, ensure excellent quality, and reduce down time in industry.
Where the application demands more from the sensor, such as use in high temperature areas, ATEX applications, pharmaceutical, chemical or food industry, please refer to Rechner’s high performance standard series of high-tech capacitive sensors.
RECHNER SENSORS - capacitive sensing technology. NormLine most typical applications include level control of: - Liquids: water, waste water, oil and grease.
- Solids: granulate, pellets, chips and powder.
Download the Rechner Sensors NormLine product catalogue (605K). | 
|
|
|
| NormLine sensors |
|
|
|
|
|
| Rechner Sensors - Germany | | Connection | PVC cable, 2m | | Output signal | KAS-70..A NPN NO+NC KAS-70..S NPN NO KAS-80..A PNP NO+NC KAS-80..S PNP NO | | Operating voltage | 10 to 30 V DC | | Diameter | M18 x 1 | | Installation | Non-flush mountable | | Housing material | PA/PPO | | Operating distance Sn (mm) | 8 | | Operating distance Smax (mm) | 10 | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 50Hz | | Certification | CE, RoHS, UL/CSA |
|
|
NormLine M18 plastic capactive sensor
|
|
 |
|
|
|
| Rechner Sensors - Germany | | Connection | PVC cable, 2m | | Output signal | KAS-70..A NPN NO+NC KAS-70..S NPN NO KAS-80..A PNP NO+NC KAS-80..S PNP NO | | Operating voltage | 10 to 30 V DC | | Diameter | M30 x 1 | | Installation | Non-flush mountable | | Housing material | PA/PPO | | Operating distance Sn (mm) | 15 | | Operating distance Smax (mm) | 25 | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 50Hz | | Certification | CE, RoHS, UL/CSA |
|
|
NormLine M30 plastic capactive sensor
|
|
 |
|
|
|
| Rechner Sensors - Germany | | Connection | PVC cable, 2m | | Output signal | KAS-70..A NPN NO+NC KAS-70..S NPN NO KAS-80..A PNP NO+NC KAS-80..S PNP NO | | Operating voltage | 10 to 30 V DC | | Diameter | M30 x 1 | | Installation | Non-flush mountable | | Housing material | Face PA/PPO, body Brass | | Operating distance Sn (mm) | 15 | | Operating distance Smax (mm) | 25 | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 50Hz | | Certification | CE, RoHS, UL/CSA |
|
|
NormLine M30 metal capactive sensor
|
|
 |
|
|
|
| Rechner Sensors - Germany | | Connection | M12 plug | | Output signal | KAS-70..A NPN NO+NC KAS-80..A PNP NO+NC | | Operating voltage | 10 to 30 V DC | | Diameter | M30 x 1 | | Installation | Non-flush mountable | | Housing material | PA/PPO | | Operating distance Sn (mm) | 15 | | Operating distance Smax (mm) | 25 | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 50Hz | | Certification | CE, RoHS, UL/CSA |
|
|
NormLine M30 plastic capactive sensor with plug
|
|
 |
|
|
|
| Rechner Sensors - Germany | | Connection | M12 plug | | Output signal | KAS-70..A NPN NO+NC KAS-80..A PNP NO+NC | | Operating voltage | 10 to 30 V DC | | Diameter | M30 x 1 | | Installation | Non-flush mountable | | Housing material | Face PA/PPO, body Brass | | Operating distance Sn (mm) | 15 | | Operating distance Smax (mm) | 25 | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 50Hz | | Certification | CE, RoHS, UL/CSA |
|
|
NormLine M30 metal capactive sensor with plug
|
|
 |
|
|
|
|
|
Special offers |
|
Sensors |
|
Motor Control Solutions |
|
Safety Products |
|
Shaft Encoders |
|
Switchgear & Panel Indicators
|
|
Instrumentation |
|
DIN Rail Terminals |
|
Power Supplies |
|
RFID |
|
Batteries
|
|
Electronic Housings |
|
Serial interface connectors |
|
Interface relays |
|
Surge Protection |
|
|