|
|
|
| Home |
|
| About Seltec |
|
|
Special offers
|
|
|
Sensors
|
|
|
Motor Control Solutions
|
|
|
Safety Products
|
|
|
Shaft Encoders
|
|
|
Switchgear & Panel Indicators
|
|
|
Instrumentation
|
|
|
DIN Rail Terminals
|
|
|
Power Supplies
|
|
|
RFID
|
|
|
Electronic Housings
|
|
|
PCB terminals - COMBICON
|
|
|
Serial interface connectors
|
|
|
Interface relays
|
|
|
Surge Protection
|
|
|
Industrial Ethernet
|
|
|
Energy Monitoring
|
|
|
Cable management
|
|
|
Tools
|
|
|
Photovoltaic Products
|
|
| Manufacturers List |
|
| Downloads |
|
| News |
|
| Recruitment |
|
| Contact Us |
|
|
|
|
|

|
| PRODUCTS |
|
NormLine sensors
Rechner Sensors LOW COST standard capacitive sensors.
Capacitive sensors just like inductive and optical sensors are subject to a harmonised norm IEC 60947-5-2. All the main important technical data and features are stated within this norm. Meeting these standards makes life easy for the user with regard to selection and replacement of sensors.
NormLine sensors guarantee a free trade in the common market, ensure excellent quality, and reduce down time in industry.
Where the application demands more from the sensor, such as use in high temperature areas, ATEX applications, pharmaceutical, chemical or food industry, please refer to Rechner’s high performance standard series of high-tech capacitive sensors.
RECHNER SENSORS - capacitive sensing technology. NormLine most typical applications include level control of: - Liquids: water, waste water, oil and grease.
- Solids: granulate, pellets, chips and powder.
Download the Rechner Sensors NormLine product catalogue (605K). | 
|
|
|
| NormLine sensors |
|
|
|
|
|
| Rechner Sensors - Germany | KA0368 KAS-70-A23-S-K-NL KA0362 KAS-70-A23-A-K-NL KA0324 KAS-80-A23-S-K-NL KA0325 KAS-80-A23-A-K-NL | NPN N/O NPN NO+NC PNP N/O PNP NO+NC | | Connection | PVC cable, 2m | | Output signal | KAS-70..A NPN NO+NC KAS-80..A PNP NO+NC | | Operating voltage | 10 to 30 V DC | | Diameter | M18 x 1 | | Installation | Non-flush mountable | | Housing material | PA/PPO | | Operating distance Sn (mm) | 8 | | Operating distance Smax (mm) | 10 | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 50Hz | | Certification | CE, RoHS, UL/CSA |
|
|
NormLine M18 plastic capactive sensor
|
|
 |
|
|
|
| Rechner Sensors - Germany | KA0367 KAS-70-A24-S-K-NL KA0364 KAS-70-A24-A-K-NL KA0326 KAS-80-A24-S-K-NL KA0327 KAS-80-A24-A-K-NL | NPN N/O NPN NO+NC PNP N/O PNP NO+NC | | Connection | PVC cable, 2m | | Output signal | KAS-70..A NPN NO+NC KAS-70..S NPN NO KAS-80..A PNP NO+NC KAS-80..S PNP NO | | Operating voltage | 10 to 30 V DC | | Diameter | M30 x 1.5 | | Installation | Non-flush mountable | | Housing material | PA/PPO | | Operating distance Sn (mm) | 15 | | Operating distance Smax (mm) | 25 | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 50Hz | | Certification | CE, RoHS, UL/CSA |
|
|
NormLine M30 plastic capactive sensor
|
|
 |
|
|
|
| Rechner Sensors - Germany | KA0366 KAS-70-A24-S-NL KA0360 KAS-70-A24-A-NL KA0334 KAS-80-A24-S-NL KA0335 KAS-80-A24-A-NL | NPN N/O NPN NO+NC PNP N/O PNP NO+NC | | Connection | PVC cable, 2m | | Output signal | KAS-70..A NPN NO+NC KAS-70..S NPN NO KAS-80..A PNP NO+NC KAS-80..S PNP NO | | Operating voltage | 10 to 30 V DC | | Diameter | M30 x 1.5 | | Installation | Non-flush mountable | | Housing material | Face PA/PPO, body Brass | | Operating distance Sn (mm) | 15 | | Operating distance Smax (mm) | 25 | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 50Hz | | Certification | CE, RoHS, UL/CSA |
|
|
NormLine M30 metal capactive sensor
|
|
 |
|
|
|
| Rechner Sensors - Germany | KA0351 KAS-70-A24-A-K-Y3-NL KA0333 KAS-80-A24-A-K-Y3-NL | NPN NO+NC PNP NO+NC | | Connection | M12 plug | | Output signal | KAS-70..A NPN NO+NC KAS-80..A PNP NO+NC | | Operating voltage | 10 to 30 V DC | | Diameter | M30 x 1.5 | | Installation | Non-flush mountable | | Housing material | PA/PPO | | Operating distance Sn (mm) | 15 | | Operating distance Smax (mm) | 25 | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 50Hz | | Certification | CE, RoHS, UL/CSA |
|
|
NormLine M30 plastic capactive sensor with plug
|
|
 |
|
|
|
| Rechner Sensors - Germany | KA0365 KAS-70-A24-A-Y3-NL KA0336 KAS-80-A24-A-Y3-NL | NPN NO+NC PNP NO+NC | | Connection | M12 plug | | Output signal | KAS-70..A NPN NO+NC KAS-80..A PNP NO+NC | | Operating voltage | 10 to 30 V DC | | Diameter | M30 x 1.5 | | Installation | Non-flush mountable | | Housing material | Face PA/PPO, body Brass | | Operating distance Sn (mm) | 15 | | Operating distance Smax (mm) | 25 | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 50Hz | | Certification | CE, RoHS, UL/CSA |
|
|
NormLine M30 metal capactive sensor with plug
|
|
 |
|
|
|
| Rechner Sensors - Germany | | KA0862 KAS-90-38-S-NL | AC NO | | Connection | 2m PVC cable
| | Output signal | 2-wire AC NO
| | Operating voltage | 20-250VAC/DC | | Diameter | 34mm smooth
| | Installation | Non-flush mountable | | Housing material | PA/PPO | | Operating distance Sn (mm) | 20
| | Operating distance Smax (mm) | 25 | | Temperature range | -25 to +70 °C | | Protection | IP67 | | Frequency | 25Hz | | Certification | CE, RoHS |
|
|
KA0862 KAS-90-38-S-NL
|
|
 |
|
|
|
|
|
Special offers |
|
Sensors |
|
Motor Control Solutions |
|
Safety Products |
|
Shaft Encoders |
|
Switchgear & Panel Indicators |
|
Instrumentation |
|
DIN Rail Terminals |
|
Power Supplies |
|
RFID |
|
Electronic Housings |
|
PCB terminals - COMBICON |
|
Serial interface connectors |
|
Interface relays |
|
Surge Protection |
|
Industrial Ethernet |
|
Energy Monitoring |
|
Cable management |
|
Tools |
|
Photovoltaic Products |
|
|