YOUR ACCOUNT
BASKET
CHECKOUT
AUTOMATION & CONTROL DISTRIBUTORS
T: 01482 225297 email: sales@seltec.co.uk
Unit G, Venture Business Park
Witty Street
Hull
HU3 4EL
United Kingdom

Search Products



Subscribe to Newsletter

Enter your email address in the box above to receive monthly newsletters from us.
Phoenix Contact MCR signal conditionersPhoenix Contact
PRODUCTS

Phoenix Contact MCR

We are adding items to this section. If you require a part from this range that isn't listed here, please contact us.

  Phoenix Contact MCR    
Phoenix Contact 2814537 MCR-U-I-4-DC
MCR 3-way isolating amplifier, for electrical isolation of analog signals, input signal: 0-10 V, output signal: 4..20 mA
  • Phoenix Contact - Germany 
  • Configurable/programmable: No
  • Input signal: 0-10V
  • Output signal: 4-20mA
  • Power supply: 20-30Vdc
  2814537 MCR-U-I-4-DC  
Phoenix Contact 2814605 MCR-F-UI-DC
MCR frequency measuring transducer, programmable, for converting frequencies into analog signals, with 3-way isolation and configurable output
  • Phoenix Contact - Germany
  • Configurable/programmable: Yes
  • Input signal: Frequency input 0.1-120kHz
  • Input sources: NPN/PNP, NAMUR, contact inputs
  • Output signal: Voltage (10V) or current (20mA)
  • Power supply: 20-30Vdc
  2814605 MCR-F-UI-DC  
Phoenix Contact 2814715 MCR-S-1-5-UI-DCI-NC
MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, input current 0-0.5 to 0-10A, unconfigured
  • Phoenix Contact - Germany
  • Configurable/programmable: Yes
  • Input signal: AC, DC or distorted current sources
  • Input current range: 0-11A
  • Output signal: Voltage (10V) or current (20mA)
  • Power supply: 20-30Vdc
  2814715 MCR-S-1-5-UI-DCI-NC  
Phoenix Contact 2814728 MCR-S10-50-UI-DCI-NC
MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, input current 0-10 to 0-50A, unconfigured
  • Phoenix Contact - Germany
  • Configurable/programmable: Yes
  • Input signal: AC, DC or distorted current sources
  • Input current range: 0-55A
  • Output signal: Voltage (10V) or current (20mA)
  • Power supply: 20-30Vdc
  2814728 MCR-S10-50-UI-DCI-NC  
Phoenix Contact 2814731 MCR-S-1-5-UI-SW-DCI-NC
MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, with relay and transistor output, input current 0-0.5 to 0-10 A, unconfigured
  • Phoenix Contact - Germany
  • Configurable/programmable: Yes
  • Input signal: AC, DC or distorted current sources
  • Input current range: 0-11A
  • Output signal: Voltage (10V) or current (20mA)
  • Switching output: Relay and PNP transistor.
  • Power supply: 20-30Vdc
  2814731 MCR-S-1-5-UI-SW-DCI-NC  
Phoenix Contact 2814744 MCR-S10-50-UI-SW-DCI-NC
MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, input current 0-10 to 0-50A, unconfigured
  • Phoenix Contact - Germany
  • Configurable/programmable: Yes
  • Input signal: AC, DC or distorted current sources
  • Input current range: 0-55A
  • Output signal: Voltage (10V) or current (20mA)
  • Switching output: Relay and PNP transistor
  • Power supply: 20-30Vdc
  2814744 MCR-S10-50-UI-SW-DCI-NC  
Phoenix Contact 2814838 MCR-FL-C-UI-UI-DCI-24/230
MCR 3-way isolating amplifier, with configurable inputs/outputs, reliable isolation and wide-range supply, for electrical isolation of analog signals
  • Phoenix Contact - Germany
  • Configurable/programmable: Yes
  • Input signal: 0-10V, 0-20mA/4-20mA
  • Output signal: Voltage (0-10V) or current (0/4-20mA)
  • Power supply: 20V AC/DC-253V AC/DC
  2814838 MCR-FL-C-UI-UI-DCI-24/230  
Phoenix Contact 2814867 MCR-FL-C-UI-2UI-DCI-NC
MCR signal multiplier/splitter, for doubling and electrical isolation of analog signals, unconfigured
  • Phoenix Contact - Germany
  • Send one input signal to two different locations
  • Configurable/programmable: Yes
  • Input signal:
       0mA-24mA (freely selectable in 0.1mA steps)
       0V-12V (freely selectable in 0.1V steps)
  • Output signal: Voltage (15V max) or current (35mA max)
  • Power supply: 20-30VDC
  2814867 MCR-FL-C-UI-2UI-DCI-NC  
Phoenix Contact 2766465 MCR-SWS-U
MCR threshold value switches, with adjustable hysteresis and relay/transistor output, input signal 0-10V
  • Phoenix Contact - Germany
  • Trigger output with input value is reached
  • Adjustable threshold pointand hysteresis
  • Input signal: 0V-10V
  • Output signal: Relay and 3 PNP transistor outputs
  • Transistor outputs give status of 'Below', 'In' and 'Above' threshold value
  • Power supply: 20-30VDC
  2766465 MCR-SWS-U  
Phoenix Contact 2766478 MCR-SWS-I
MCR threshold value switches, with adjustable hysteresis and relay/transistor output, input signal 0/4-20mA
  • Phoenix Contact - Germany
  • Trigger output with input value is reached
  • Adjustable threshold pointand hysteresis
  • Input signal: 0/4-20mA
  • Output signal: Relay and 3 PNP transistor outputs
  • Transistor outputs give status of 'Below', 'In' and 'Above' threshold value
  • Power supply: 20-30VDC
  2766478 MCR-SWS-I  
Phoenix Contact 2769653 MCR-R-I-4-V-DC
MCR potentiometer position indicator transducer, with electrical isolation of supply voltage, for slider position signaling on a potentiometer, input 0-100 Ohm to 0-20kOhm, output signal 4-20mA
  • Phoenix Contact - Germany
  • Slidewire feedback or tranducer 
  • Input signal: 0-100R or 0-20K ohm
  • Output signal: 4-20mA
  • Power supply: 20-30VDC
  2769653 MCR-R-I-4-V-DC