| Power MCR |
|
|
|
|
|
MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, input current 0-0.5 to 0-10A, unconfigured |
|
- Phoenix Contact - Germany
- Configurable/programmable: Yes
- Input signal: AC, DC or distorted current sources
- Input current range: 0-11A
- Output signal: Voltage (10V) or current (20mA)
- Power supply: 20-30Vdc
|
|
2814715 MCR-S-1-5-UI-DCI-NC
|
|
 |
|
|
|
MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, input current 0-10 to 0-50A, unconfigured |
|
- Phoenix Contact - Germany
- Configurable/programmable: Yes
- Input signal: AC, DC or distorted current sources
- Input current range: 0-55A
- Output signal: Voltage (10V) or current (20mA)
- Power supply: 20-30Vdc
|
|
2814728 MCR-S10-50-UI-DCI-NC
|
|
 |
|
|
|
MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, with relay and transistor output, input current 0-0.5 to 0-10 A, unconfigured |
|
- Phoenix Contact - Germany
- Configurable/programmable: Yes
- Input signal: AC, DC or distorted current sources
- Input current range: 0-11A
- Output signal: Voltage (10V) or current (20mA)
- Switching output: Relay and PNP transistor.
- Power supply: 20-30Vdc
|
|
2814731 MCR-S-1-5-UI-SW-DCI-NC
|
|
 |
|
|
|
MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, input current 0-10 to 0-50A, unconfigured |
|
- Phoenix Contact - Germany
- Configurable/programmable: Yes
- Input signal: AC, DC or distorted current sources
- Input current range: 0-55A
- Output signal: Voltage (10V) or current (20mA)
- Switching output: Relay and PNP transistor
- Power supply: 20-30Vdc
|
|
2814744 MCR-S10-50-UI-SW-DCI-NC
|
|
 |
|
|
|
MCR current measuring transducer, for measuring sinusoidal and non-sinusoidal alternating currents, input current 0-100A, output voltage 0-(5) 10 V or 4-20mA loop-powered.
|
|
- Phoenix Contact
- Input current: 0 to 50/75/100A
Switch selectable. - Output:
0-5V or 0-10V (model ..-U) 4-20mA loop-powered (model ..-I-LP) - True r.m.s. value measurement from 30-6000Hz
- Can be retrofitted using the split Rogowski coil
- Through connection of cable up to 18mm diameter
- Electrical isolation of input and output
|
|
MCR-SL-S-100-U ..-I-LP
|
|
 |
|
|
|
MCR current measuring transducer, for measuring sinusoidal and non-sinusoidal alternating currents, input current 0-200A, output voltage 0-(5) 10 V or 4-20mA loop-powered.
|
|
- Phoenix Contact
- Input current: 0 to 100/150/200A
Switch selectable. - Output:
0-5V or 0-10V (model ..-U) 4-20mA loop-powered (model ..-I-LP) - True r.m.s. value measurement from 30-6000Hz
- Can be retrofitted using the split Rogowski coil
- Through connection of cable up to 18mm diameter
- Electrical isolation of input and output
|
|
MCR-SL-S-200-U ..-I-LP
|
|
 |
|
|
|
MCR current measuring transducer, for measuring sinusoidal and non-sinusoidal alternating currents, input current 0-400A, output voltage 0-(5) 10 V or 4-20mA loop-powered.
|
|
- Phoenix Contact
- Input current: 0 to 200/300/400A
Switch selectable. - Output:
0-5V or 0-10V (model ..-U) 4-20mA loop-powered (model ..-I-LP) - True r.m.s. value measurement from 30-6000Hz
- Can be retrofitted using the split Rogowski coil
- Through connection of cable up to 18mm diameter
- Electrical isolation of input and output
|
|
MCR-SL-S-400-U ..-I-LP
|
|
 |