| IFM IN 40x12 |
|
|
|
|
|
| IFM Electronic - Germany | IN0073 IN-2002-ABOA Inductive sensor AC/DC N/O, 2mm, Flush, 2m cable | | Output signal | AC/DC 2-wire Normally open | | Housing material | PBT plastic | | Connection | Cable, 2M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Flush | | Sensing range Sn (mm) | 2.0 | | Frequency | 25Hz (AC), 50Hz (DC) | | Protection | IP67 | | Operating voltage | 20-250-Vac/dc | | Temperature | -25 to +80C |
|
|
IFM IN-2002-ABOA (IN0073)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN0074 IN-2002-ABOA/6M Inductive sensor AC/DC N/O, 2mm, Flush, 6m cable | | Output signal | AC/DC 2-wire Normally open | | Housing material | PBT plastic | | Connection | Cable, 6M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Flush | | Sensing range Sn (mm) | 2.0 | | Frequency | 25Hz (AC), 50Hz (DC) | | Protection | IP67 | | Operating voltage | 20-250-Vac/dc | | Temperature | -25 to +80C |
|
|
IFM IN-2002-ABOA/6M (IN0074)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN0077 IN-2002-BBOA Inductive sensor AC/DC N/C, 2mm, Flush, 2m cable | | Output signal | AC/DC 2-wire Normally closed | | Housing material | PBT plastic | | Connection | Cable, 2M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Flush | | Sensing range Sn (mm) | 2.0 | | Frequency | 25Hz (AC), 50Hz (DC) | | Protection | IP67 | | Operating voltage | 20-250-Vac/dc | | Temperature | -25 to +80C |
|
|
IFM IN-2002-BBOA (IN0077)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN0081 IN-2004-ABOA Inductive sensor AC/DC N/O, 4mm, Non-flush, 2m cable | | Output signal | AC/DC 2-wire Normally open | | Housing material | PBT plastic | | Connection | Cable, 2M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 4.0 | | Frequency | 25Hz (AC), 50Hz (DC) | | Protection | IP67 | | Operating voltage | 20-250-Vac/dc | | Temperature | -25 to +80C |
|
|
IFM IN-2004-ABOA (IN0081)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN0082 IN-2004-ABOA/6M Inductive sensor AC/DC N/O, 4mm, Non-flush, 6m cable | | Output signal | AC/DC 2-wire Normally open | | Housing material | PBT plastic | | Connection | Cable, 6M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 4.0 | | Frequency | 25Hz (AC), 50Hz (DC) | | Protection | IP67 | | Operating voltage | 20-250-Vac/dc | | Temperature | -25 to +80C |
|
|
IFM IN-2004-ABOA/6M (IN0082)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN0085 IN-2004-BBOA Inductive sensor AC/DC N/C, 4mm, Non-flush, 2m cable | | Output signal | AC/DC 2-wire Normally closed | | Housing material | PBT plastic | | Connection | Cable, 2M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 4.0 | | Frequency | 25Hz (AC), 50Hz (DC) | | Protection | IP67 | | Operating voltage | 20-250-Vac/dc | | Temperature | -25 to +80C |
|
|
IFM IN-2004-BBOA (IN0085)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN0086 IN-2004-BBOA/6M Inductive sensor AC/DC N/C, 4mm, Non-flush, 6m cable | | Output signal | AC/DC 2-wire Normally closed | | Housing material | PBT plastic | | Connection | Cable, 6M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 4.0 | | Frequency | 25Hz (AC), 50Hz (DC) | | Protection | IP67 | | Operating voltage | 20-250-Vac/dc | | Temperature | -25 to +80C |
|
|
IFM IN-2004-BBOA/6M (IN0086)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN502A IN-3002-BPKG/3D Inductive sensor, ATEX approval, 3D PNP, N/O, 2mm, Flush, 2m cable, ATEX | | Output signal | PNP Normally open | | Housing material | PBT plastic | | Connection | Cable, 2M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Flush | | Sensing range Sn (mm) | 2.0 | | Frequency | 1.4KHz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | -20 to +60C |
|
|
IFM IN-3002-BPKG/3D (IN502A)
|
|
 |
|
|
|
| IFM Electronic - Germany |
IN5028 IN-3004-FPKG Inductive sensor - PNP, N/O or N/C, 4mm, Non-flush, terminal block Special price (only one) |
| Output signal |
PNP Normally open/normally closed |
| Housing material |
PBT plastic |
| Connection |
Terminal block |
| Housing |
12x26mm Cuboid / slab |
| Length (mm) |
40.0 |
| Installation |
Non-flush |
| Sensing range Sn (mm) |
4.0 |
| Frequency |
1.3KHz |
| Protection |
IP67 |
| Operating voltage |
18-30Vdc |
| Temperature |
-25 to +80C |
|
|
IFM IN-3004-FPKG (IN5028)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5121 IN-3002-BPKG Inductive sensor PNP, N/O, 2mm, Flush, 2m cable | | Output signal | PNP Normally open | | Housing material | PBT plastic | | Connection | Cable, 2M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Flush | | Sensing range Sn (mm) | 2.0 | | Frequency | 1.4KHz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-3002-BPKG (IN5121)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5122 IN-3002-BPKG/6M Inductive sensor PNP, N/O, 2mm, Flush, 6m cable | | Output signal | PNP Normally open | | Housing material | PBT plastic | | Connection | Cable, 6M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Flush | | Sensing range Sn (mm) | 2.0 | | Frequency | 1.4KHz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-3002-BPKG/6M (IN5122)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5125 IN-3002-ANKG Inductive sensor NPN, N/O, 2mm, Flush, 2m cable | | Output signal | NPN Normally open | | Housing material | PBT plastic | | Connection | Cable, 2M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Flush | | Sensing range Sn (mm) | 2.0 | | Frequency | 1.4KHz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-3002-ANKG (IN5125)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5129 IN-3004-BPKG Inductive sensor PNP, N/O, 4mm, Non-flush, 2m cable | | Output signal | PNP Normally open | | Housing material | PBT plastic | | Connection | Cable, 2M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 4.0 | | Frequency | 1.3KHz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-3004-BPKG (IN5129)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5130 IN-3004-BPKG/6M Inductive sensor PNP, N/O, 4mm, Non-flush, 6m cable | | Output signal | PNP Normally open | | Housing material | PBT plastic | | Connection | Cable, 6M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 4.0 | | Frequency | 1.3KHz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-3004-BPKG/6M (IN5130)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5133 IN-3004-ANKG Inductive sensor NPN, N/O, 4mm, Non-flush, 2m cable | | Output signal | NPN Normally open | | Housing material | PBT plastic | | Connection | Cable, 2M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 4.0 | | Frequency | 1.3KHz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-3004-ANKG (IN5133)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5186 IN-3002-APKG Inductive sensor PNP, N/C, 2mm, Flush, 2m cable | | Output signal | PNP Normally closed | | Housing material | PBT plastic | | Connection | Cable, 2M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Flush | | Sensing range Sn (mm) | 2.0 | | Frequency | 1.4KHz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-3002-APKG (IN5186)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5189 IN-3004-BNKG Inductive sensor PNP, N/C, 4mm, Non-flush, 2m cable | | Output signal | PNP Normally closed | | Housing material | PBT plastic | | Connection | Cable, 2M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 4.0 | | Frequency | 1.3KHz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-3004-APKG (IN5188)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5189 IN-3004-BNKG Inductive sensor NPN, N/C, 4mm, Non-flush, 2m cable | | Output signal | NPN Normally closed | | Housing material | PBT plastic | | Connection | Cable, 2M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 4.0 | | Frequency | 1.3KHz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-3004-BNKG (IN5189)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5207 IN-2002-FRKG/PH Inductive sensor PNP/NPN, N/O or N/C, 2mm, Flush, 2m cable, 'Quadronorm' | | Output signal | 2 wire DC PNP/NPN normally open/normally closed | | Housing material | PBT plastic | | Connection | Cable, 2M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Flush | | Sensing range Sn (mm) | 2.0 | | Frequency | 1.3KHz | | Protection | IP67 | | Operating voltage | 10-55Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-2002-FRKG/PH (IN5207)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5208 IN-2004-FRKG/PH Inductive sensor PNP/NPN, N/O or N/C, 4mm, Non-flush, 2m cable, 'Quadronorm' | | Output signal | 2 wire DC PNP/NPN normally open/normally closed | | Housing material | PBT plastic | | Connection | Cable, 2M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 4.0 | | Frequency | 1.2KHz | | Protection | IP67 | | Operating voltage | 10-55Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-2004-FRKG/PH (IN5208)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5212 IN-3004-BPKG/AS-610-TPS Inductive sensor PNP, N/O, 4mm, Non-flush, M8 plug | | Output signal | PNP Normally open | | Housing material | PBT plastic | | Connection | M8 plug | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 4.0 | | Frequency | 1.3KHz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-3004-BPKG/AS-610-TPS (IN5212)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5223 IN-3004-APKG/6M/PH Inductive sensor PNP, N/C, 4mm, Non-flush, 6m cable | | Output signal | PNP Normally closed | | Housing material | PBT plastic | | Connection | Cable, 6M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 4.0 | | Frequency | 1.3KHz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-3004-APKG/6M/PH (IN5223)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5228 IN-2004-FRKG/6M/PH Inductive sensor PNP/NPN, N/O or N/C, 4mm, Non-flush, 6m cable, 'Quadronorm' | | Output signal | 2 wire DC PNP/NPN normally open/normally closed | | Housing material | PBT plastic | | Connection | Cable, 6M | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 4.0 | | Frequency | 1.2KHz | | Protection | IP67 | | Operating voltage | 10-55Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-2004-FRKG/6M/PH (IN5228)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5230 IN-3002-BPKG/AS-610-TPS Inductive sensor PNP, N/O, 2mm, Flush, M8 plug | | Output signal | PNP Normally open | | Housing material | PBT plastic | | Connection | M8 plug | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Flush | | Sensing range Sn (mm) | 2.0 | | Frequency | 1.4KHz | | Protection | IP67 | | Operating voltage | 10-36Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-3002-BPKG/AS-610-TPS (IN5230)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5258 IN-2004-FRKG/AS-610-T Inductive sensor PNP/NPN, N/O or N/C, 4mm, Non-flush, M8 plug, 'Quadronorm' | | Output signal | 2 wire DC PNP/NPN normally open/normally closed | | Housing material | PBT plastic | | Connection | M8 plug | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Non-flush | | Sensing range Sn (mm) | 4.0 | | Frequency | 1.2KHz | | Protection | IP67 | | Operating voltage | 10-55Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-2004-FRKG/AS-610-T (IN5258)
|
|
 |
|
|
|
| IFM Electronic - Germany | IN5269 IN-2002-FRKG/AS-610-TRF Inductive sensor PNP/NPN, N/O or N/C, 2mm, Flush, M8 plug, 'Quadronorm' | | Output signal | 2 wire DC PNP/NPN normally open/normally closed | | Housing material | PBT plastic | | Connection | M8 plug | | Housing | 12x26mm Cuboid / slab | | Length (mm) | 40.0 | | Installation | Flush | | Sensing range Sn (mm) | 2.0 | | Frequency | 1.3KHz | | Protection | IP67 | | Operating voltage | 10-55Vdc | | Temperature | -25 to +80C |
|
|
IFM IN-2002-FRKG/AS-610-TRF (IN5269)
|
|
 |