  Series 600 - Standard sensors    
Contrinex DW-?D-60?-M30-120 Inductive sensor
    Contrinex - Switzerland
    DW-AD-601-M30-120
    DW-AD-602-M30-120
    DW-AD-603-M30-120
    DW-AD-604-M30-120
    DW-DD-605-M30-120
    DW-DD-606-M30-120
    NPN N.O. 3 wire 
    NPN N.C. 3 wire
    PNP N.O. 3 wire
    PNP N.C. 3 wire
    N.O. 2-wire
    N.C. 2-wire
    Output signalPNP, NPN, NO, NC
    Housing materialChrome-plated brass
    Connection PVC cable, 2m
    DiameterM30
    Length (mm)35
    InstallationEmbeddable
    Operating distance Sn (mm)10
    Frequency850Hz (3-wire)
    600Hz (2-wire)
    ProtectionIP67
    Operating voltage10-30VDC (3-wire)
    10-65VDC (2-wire)
    Temperature-25 to +70C
  DW-?D-60?-M30-120 Inductive sensor  
Contrinex DW-?D-60?-M30 Inductive sensor
    Contrinex - Switzerland
    DW-AD-601-M30
    DW-AD-602-M30
    DW-AD-603-M30
    DW-AD-604-M30
    DW-DD-605-M30
    DW-DD-606-M30
    NPN N.O. 3 wire 
    NPN N.C. 3 wire
    PNP N.O. 3 wire
    PNP N.C. 3 wire
    N.O. 2-wire
    N.C. 2-wire
    Output signalPNP, NPN, NO, NC
    Housing materialChrome-plated brass
    Connection PVC cable, 2m
    DiameterM30
    Length (mm)50
    InstallationEmbeddable
    Operating distance Sn (mm)10
    Frequency850Hz (3-wire)
    600Hz (2-wire)
    ProtectionIP67
    Operating voltage10-30VDC (3-wire)
    10-65VDC (2-wire)
    Temperature-25 to +70C
  DW-?D-60?-M30 Inductive sensor  
Contrinex DW-AD-60?-M30 AC/DC Inductive Sensor
    Contrinex - Switzerland
    DW-AD-607-M30
    DW-AD-608-M30
    AC/DC N.O. 2 wire 
    AC/DC N.C. 2 wire
    Output signalNO, NC
    Housing materialNickel-plated brass
    Connection PUR cable, 2m
    DiameterM30
    Length (mm)54
    InstallationEmbeddable
    Operating distance Sn (mm)10
    Frequency25Hz(AC)
    200Hz(DC)
    ProtectionIP67
    Operating voltage20-265VAC
    20-320VDC
    Temperature-25 to +85C
  DW-AD-60?-M30 AC/DC Inductive Sensor  
Contrinex DW-?S-60?-M30-120 Inductive sensor
    Contrinex - Switzerland
    DW-AS-601-M30-120
    DW-AS-602-M30-120
    DW-AS-603-M30-120
    DW-AS-604-M30-120
    DW-DS-605-M30-120
    DW-DS-606-M30-120
    NPN N.O. 3 wire 
    NPN N.C. 3 wire
    PNP N.O. 3 wire
    PNP N.C. 3 wire
    N.O. 2-wire
    N.C. 2-wire
    Output signalPNP, NPN, NO, NC
    Housing materialChrome-plated brass
    Connection M12 connector
    DiameterM30
    Length (mm)48
    InstallationEmbeddable
    Operating distance Sn (mm)10
    Frequency850Hz (3-wire)
    600Hz (2-wire)
    ProtectionIP67
    Operating voltage10-30VDC (3-wire)
    10-65VDC (2-wire)
    Temperature-25 to +70C
  DW-?S-60?-M30-120 Inductive sensor  
Contrinex DW-?S-60?-M30-002 Inductive sensor
    Contrinex - Switzerland
    DW-AS-601-M30-002
    DW-AS-602-M30-002
    DW-AS-603-M30-002
    DW-AS-604-M30-002
    DW-DS-605-M30-002
    DW-DS-606-M30-002
    NPN N.O. 3 wire 
    NPN N.C. 3 wire
    PNP N.O. 3 wire
    PNP N.C. 3 wire
    N.O. 2-wire
    N.C. 2-wire
    Output signalPNP, NPN, NO, NC
    Housing materialChrome-plated brass
    Connection M12 connector
    DiameterM30
    Length (mm)63.5
    InstallationEmbeddable
    Operating distance Sn (mm)10
    Frequency850Hz (3-wire)
    600Hz (2-wire)
    ProtectionIP67
    Operating voltage10-30VDC (3-wire)
    10-65VDC (2-wire)
    Temperature-25 to +70C
  DW-?S-60?-M30-002 Inductive sensor  
Contrinex DW-AD-60?-M30-002 AC/DC Inductive Sensor
    Contrinex - Switzerland
    DW-AS-607-M30-002
    DW-AS-608-M30-002
    AC/DC N.O. 2 wire 
    AC/DC N.C. 2 wire
    Output signalNO, NC
    Housing materialNickel-plated brass
    Connection M12 connector
    DiameterM30
    Length (mm)69
    InstallationEmbeddable
    Operating distance Sn (mm)10
    Frequency25Hz(AC)
    200Hz(DC)
    ProtectionIP67
    Operating voltage20-265VAC
    20-320VDC
    Temperature-25 to +85C
  DW-AS-60?-M30-002 AC/DC Inductive Sensor  
Contrinex DW-?D-61?-M30-120 Inductive sensor
Contrinex - Switzerland
DW-AD-611-M30-120
DW-AD-612-M30-120
DW-AD-613-M30-120
DW-AD-614-M30-120
DW-DD-615-M30-120
DW-DD-616-M30-120
NPN N.O. 3 wire 
NPN N.C. 3 wire
PNP N.O. 3 wire
PNP N.C. 3 wire
N.O. 2-wire
N.C. 2-wire
Output signal PNP, NPN, NO, NC
Housing material Chrome-plated brass
Connection PVC cable, 2m
Diameter M30
Length (mm) 35
Installation Non-embeddable
Operating distance Sn (mm) 15
Frequency 850Hz (3-wire)
500Hz (2-wire)
Protection IP67
Operating voltage 10-30VDC (3-wire)
10-65VDC (2-wire)
Temperature -25 to +70C

  DW-?D-61?-M30-120 Inductive sensor  
Contrinex DW-?D-61?-M30 Inductive sensor
    Contrinex - Switzerland
    DW-AD-611-M30
    DW-AD-612-M30
    DW-AD-613-M30
    DW-AD-614-M30
    DW-DD-615-M30
    DW-DD-616-M30
    NPN N.O. 3 wire 
    NPN N.C. 3 wire
    PNP N.O. 3 wire
    PNP N.C. 3 wire
    N.O. 2-wire
    N.C. 2-wire
    Output signalPNP, NPN, NO, NC
    Housing materialChrome-plated brass
    Connection PVC cable, 2m
    DiameterM30
    Length (mm)50
    InstallationNon-embeddable
    Operating distance Sn (mm)15
    Frequency850Hz (3-wire)
    500Hz (2-wire)
    ProtectionIP67
    Operating voltage10-30VDC (3-wire)
    10-65VDC (2-wire)
    Temperature-25 to +70C
  DW-?D-61?-M30 Inductive sensor  
Contrinex DW-AD-61?-M30 AC/DC Inductive Sensor
    Contrinex - Switzerland
    DW-AD-617-M30
    DW-AD-618-M30
    AC/DC N.O. 2 wire 
    AC/DC N.C. 2 wire
    Output signalNO, NC
    Housing materialNickel-plated brass
    Connection PUR cable, 2m
    DiameterM30
    Length (mm)54
    InstallationNon-embeddable
    Operating distance Sn (mm)15
    Frequency25Hz(AC)
    220Hz(DC)
    ProtectionIP67
    Operating voltage20-265VAC
    20-320VDC
    Temperature-25 to +85C
  DW-AD-61?-M30 AC/DC Inductive Sensor  
Contrinex DW-?S-61?-M30-120 Inductive sensor
    Contrinex - Switzerland
    DW-AS-611-M30-120
    DW-AS-612-M30-120
    DW-AS-613-M30-120
    DW-AS-614-M30-120
    DW-DS-615-M30-120
    DW-DS-616-M30-120
    NPN N.O. 3 wire 
    NPN N.C. 3 wire
    PNP N.O. 3 wire
    PNP N.C. 3 wire
    N.O. 2-wire
    N.C. 2-wire
    Output signalPNP, NPN, NO, NC
    Housing materialChrome-plated brass
    Connection M12 connector
    DiameterM30
    Length (mm)48.5
    InstallationNon-embeddable
    Operating distance Sn (mm)15
    Frequency850Hz (3-wire)
    500Hz (2-wire)
    ProtectionIP67
    Operating voltage10-30VDC (3-wire)
    10-65VDC (2-wire)
    Temperature-25 to +70C
  DW-?S-61?-M30-120 Inductive sensor  
Contrinex DW-?S-61?-M30-002 Inductive sensor
    Contrinex - Switzerland
    DW-AS-611-M30-002
    DW-AS-612-M30-002
    DW-AS-613-M30-002
    DW-AS-614-M30-002
    DW-DS-615-M30-002
    DW-DS-616-M30-002
    NPN N.O. 3 wire 
    NPN N.C. 3 wire
    PNP N.O. 3 wire
    PNP N.C. 3 wire
    N.O. 2-wire
    N.C. 2-wire
    Output signalPNP, NPN, NO, NC
    Housing materialChrome-plated brass
    Connection M12 connector
    DiameterM30
    Length (mm)63.5
    InstallationNon-embeddable
    Operating distance Sn (mm)15
    Frequency850Hz (3-wire)
    500Hz (2-wire)
    ProtectionIP67
    Operating voltage10-30VDC (3-wire)
    10-65VDC (2-wire)
    Temperature-25 to +70C
  DW-?S-61?-M30-002 Inductive sensor  
Contrinex DW-AS-61?-M30-002 AC/DC Inductive Sensor
    Contrinex - Switzerland
    DW-AS-617-M30-002
    DW-AS-618-M30-002
    AC/DC N.O. 2 wire 
    AC/DC N.C. 2 wire
    Output signalNO, NC
    Housing materialNickel-plated brass
    Connection M12 connector
    DiameterM30
    Length (mm)69
    InstallationNon-embeddable
    Operating distance Sn (mm)15
    Frequency25Hz(AC)
    220Hz(DC)
    ProtectionIP67
    Operating voltage20-265VAC
    20-320VDC
    Temperature-25 to +85C
  DW-AS-61?-M30-002 AC/DC Inductive Sensor